NAP-50 and NAP-55  Catalytic Gas Sensors

Specifications

Recommended Voltage:                     2.5V  +/- 0.25V
Current Drawn:                                     170 +/- 10mA
Zero Offset:                                        0mV +/- 35mV
Minimum Sensitivity:                       30mV/% CH4/Air
Range:                                                   0-50% LEL
Accuracy:                                       +/- 1%LEL(CH4)
Maximum Long Term Drift:
   Span:                                     < +/- 1% LEL/Month
   Zero:                                          <+/- ½ mV/Month
Response Time:                      T50: 3 sec  T90: 8 sec
Temperature Range:                           -10°C to +50°C
Temperature Drift:                            (-10°C to +50°C)
Zero:                                                     < +/-2%LEL
Humidity:                         5-90%RH, non-condensing
Humidity Response:                                +/- 2%LEL
Linearity:                        Effectively linear to 50%LEL

The Nemoto NAP-50A and NAP55A are catalytic (pellistor) type flammable gas sensors supplied as matched pairs of catalytic elements mounted on a single header enclosed in a plastic housing and protected by a metal mesh. Designed as a gas sensor for use in Domestic (Residential) Gas Detectors, the sensor detects and measures the presence of flammable gases and vapours in air, in the range 0-50% of the Lower Explosive Limit (LEL) of the gas or vapour being measured.

The highly advanced and efficient production techniques developed by Nemoto means that the cost of technically superior pellistor technology, usually reserved for Industrial Applications, is now appropriate low enough for them to be used for domestic gas detectors, which have hitherto tended to use less expensive, but less stable and less selective semiconductor type gas sensors. The performance of the NAP-50A is fully compliant with internationally recognised standards for domestic explosive as detection, such as  EN-50194