ATEX Certified Gas
Detection Transmitter Heads, featuring
CYBER®
 |
Specifications
| Sensing Elements |
Nemoto NT Range Nemoto NP “S” Range Other sensors on request |
|
Analog Outputs |
3-wire 4-20mA (Double pcb only) |
|
Digital Input/Output |
RS485 or TTL (MODBUS) |
|
Signal Outputs |
Fault Signal
Supply for external Status LED |
|
Visual Indicator |
Status LED fitted on pcb |
|
Power supply |
10-30Vdc (Nominal 12V or 24V) |
Current consumption
@12V
@24V (Examples)
|
45-65mA with NT-CO
65-85mA with NP-17S
25-45mA with NT-CO
40-60mA with NP-17S |
|
Microprocessor |
12-Bit |
|
Range |
According to sensor used |
|
Response time |
According to Sensor used |
|
Temperature Range |
-10 to +50OC |
|
Humidity Range |
20-90% RH, Non condensing |
|
Pressure Range |
90-110 KPa |
|
Calibration |
Digitally, via RS485
Interface or with optional portable calibration unit |
The NET Type-3 Transmitter Head is ATEX APPROVED:
CESI 01 ATEX 066 U
|
|
The NET
Type-3 Gas
Detecting Head has been available for some years, but until now it has
been offered fitted with a sensor only, the instrument maker being
responsible for any local signal conditioning or transmitter circuitry.
Our new CYBER® pcb has been conveniently designed to fit into the Type-3
head, resulting in a very cost effective ATEX certified transmitter
product which may be used as a complete field mounted sensor. CYBER® can
be used with a whole range of Nemoto sensors, both catalytic and
electrochemical.
This datasheet should be read in conjunction with the datasheet for the
NET-Type 3 head (NET-3X-XXX) Non cyber version, The datasheet for the
internal sensor used, and the user manual for the CYBER pcb device. |
| |
Datasheet (PDF)
|
User
Manual
(PDF)
|
|
Updated on
September 06, 2006
|